hiệt kế điện tử Anritsu HD-1000 series
Hiệu: Anritsu
Xuất xứ: Japan
Model: HD-1000 series
Model HD-1100 · HD-1150
Waterproof
Waterproof specifications : Equivalent to IPX5
Protected against water jets-Water projected at all angles through a 6.3mm nozzle at a flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters.
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Model HD-1200 · HD-1250
Waterproof
Waterproof specifications : Equivalent to IPX5
Protected against water jets-Water projected at all angles through a 6.3mm nozzle at a flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters.
(*Analog output type is not Waterproof)
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Resolution change
Press the 1/0.1 key to change the resolution of readings.
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Analog output type
Model HD-1201 · HD-1251 :1mV/°C
Model HD-1202 · HD-1252 :10mV/°C
(*Not Waterproof)
Model HD-1300 · HD-1350
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Resolution change
Press the 1/0.1 key to change the resolution of readings.
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Alarm output
The thermometer gives an alarm when readings go beyond the high or low limits.
Calibration
The displayed value can be adjusted the CAL SET key.
Analog output type
Model HD-1301 · HD-1351 :1mV/°C
Model HD-1302 · HD-1352 :10mV/°C
Model HD-1400 · HD-1450
Waterproof
Waterproof specifications : Equivalent to IPX5
Protected against water jets-Water projected at all angles through a 6.3mm nozzle at a flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters.
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Model HD-1500 · HD-1550
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Resolution change
Press the 1/0.1 key to change the resolution of readings.
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Memory function
Stores readings at user-selected time intervals.
User specified time interval and the remaining amount of memory are displayed on the sub-display.
Model HD-1650
Waterproof
Waterproof specifications : Equivalent to IPX5
Protected against water jets-Water projected at all angles through a 6.3mm nozzle at a flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters.
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
°C / °F Change
Press the °C / °F key to change the temperature unit of the displayed temperature.
Model HD-1750
Waterproof
Waterproof specifications : Equivalent to IPX5
Protected against water jets-Water projected at all angles through a 6.3mm nozzle at a flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters.
HOLD
The thermometer stops measurement by theHOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Resolution change
Press the 1/0.1 key to change the resolution of readings.
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
°C / °F Change
Press the °C / °F key to change the temperature unit of the displayed temperature.
www.sieuthidungcudo.com cung cấp nhiệt kế điện tử Anritsu HD-1000 series
Chính hãng Anritsu, bảo hành 12 tháng, giá cả hợp lý, liên hệ để được tư vấn:
CÔNG TY TNHH KỸ THUẬT NHẬT PHÁT
HCM: 512-513 Officetel, Garden Gate Building, Số 8, Đường Hoàng Minh Giám, P.9, Q.Phú Nhuận
Hà Nội: Số 15, Đường Nguyễn Xiển, Phường Thanh Xuân Trung, Quân Thanh Xuân, Hà Nội.
Mr.Hai 0908 817 486 E-mail: kd1@nhatphattools.com
Website: http://sieuthidungcudo.com Website: http://muitaro.com Website: http:/nhatphattools.com